Platiau Dychwelyd Cleifion Electrolawfeddygol OEM i Oedolion|Platiau Niwtral ESU B2B|TOP{1}}RANK
B2B contract manufacturing of adult disposable split-foil electrosurgical patient return plates. Features active conductive area >130 cm2, codiad thermol<4.0C at 700mA RF (ANSI/AAMI HF18), compatible with Valleylab REM and Erbe NESSY systems, corded and non-corded tab formats.
Trosolwg Cynnyrch
Mewn cylchedau electrolawfeddygol monopolar, mae platiau dychwelyd cleifion tafladwy sy'n oedolion yn gweithredu fel casglwyr sylfaen ffin ardal fawr sy'n cau'r ddolen radio-amledd uchel (300 kHz i 1.2 MHz) rhwng yr electrod torri gweithredol a'r siasi generadur. Wedi'i gymhwyso i barthau anatomegol fasgwlaidd-fel y bicep femoris, vastus lateralis, neu gluteus maximus-mae'r pad gwasgarol yn casglu ceryntau RF sy'n dychwelyd hyd at 1.5A RMS, gan drosi fflwcs trydanol trwchus yn ddargludiad planar eang ar draws ardal ddargludol weithredol sy'n fwy na 132 cm2.
Mae dyluniadau electrod gwasgarol safonol yn torri i lawr yn ystod gweithdrefnau llawfeddygol ynni uchel, hir ar draws tri mecanwaith ffisegol:
- Edge{0}}Gdargyfeiriad Cyfredol Cyfyngiad (Gorboethi Ffin):Oherwydd bod meinwe ddynol yn gweithredu fel cyfaint deuelectrig, mae fectorau cerrynt amledd uchel yn plygu tuag at berimedr dargludol agosaf y plât. Wrth ddefnyddio dargludyddion trwch isel (<30 um foil or printed inks), high lateral sheet resistance prevents current from spreading into the center of the plate. Current converges along the entry margin, generating localized current densities exceeding 110 mA/cm2 that produce focal thermal necrosis in the stratum corneum.
- Newid Mynediad Cymhleth mewn Hollti-Cwestiynu Platiau:Mae unedau electrolawfeddygol cyfoes yn monitro ansawdd cyswllt parhaus (CQM) trwy gylchedau pont amledd uchel (100 kHz i 140 kHz). Os yw'r haneri ffoil hollt yn dangos amrywiadau gweithgynhyrchu o ran arwynebedd arwyneb neu fàs cotio hydrogel, mae'r gymhareb derbyniad cymhleth rhwng y platiau yn dod yn anghytbwys. Mae'r generadur yn dehongli'r anghymesuredd hwn fel cyswllt pad dan fygythiad, gan gloi'r weithdrefn dosbarthu ynni RF allan yng nghanol-.
- Hylif Capilari-Trac Shorting:Mewn gweithdrefnau dyfrhau agored trwm, arthrosgopig neu echdoriad hylifol, mae halwynau a gwaed cyfun yn mudo ar draws croen y claf. Os nad oes gan y gludydd perimedr ddigon o densiwn arwyneb a dwysedd hydroffobig, mae hylifau dargludol yn treiddio i'r ffin ewyn. Mae hyn yn ffurfio llwybr hylif dargludol anfwriadol rhwng y ffoil a ffrâm y bwrdd gweithredu, gan osgoi cylched monitro'r generadur a sbarduno llosgiadau cleifion ectopig.
Mae'r platfform plât dychwelyd hwn i oedolion yn defnyddio gwe ffoil alwminiwm purdeb 38 um wedi'i rolio o uchel wedi'i ffurfweddu mewn geometreg hanner hollt trydan-cytbwys. Mae'r dargludydd wedi'i araenu â matrics hydrogel polyacrylate rhwystriant isel, allwthiol wedi'i fframio â chefn polyethylen caeedig wedi'i groesgysylltu wedi'i araenu ag ymyl gludiog hydroffobig ymosodol. Yn ystod gweithrediad pŵer llawn (700 mA RF parhaus am 60 eiliad i mewn i lwyth ffisiolegol), mae cyfanswm cynnydd tymheredd meinwe yn parhau i fod yn is na 4.0C o dan amodau prawf safonol ANSI/AAMI HF18. Rydym yn contractio-cynhyrchu ffurfweddau llinynnol (wedi'u gosod â chysylltwyr dau bin wedi'u mowldio) ac amrywiadau tab heb gordyn ar gyfer OEMs dyfeisiau llawfeddygol, cyflenwyr theatr ysbyty, a dosbarthwyr brand electrolawfeddygol yn fyd-eang.
Disgrifiad Technegol a Pheirianneg
Mae gweithgynhyrchu diwydiannol platiau dychwelyd electrolawfeddygol tafladwy i oedolion yn digwydd y tu mewn i ystafelloedd glân Dosbarth 8 ardystiedig ISO 13485 gan ddefnyddio peiriannau lamineiddio cylchdro gwe llydan di-dor a pheiriannau torri marw. Mae'r Bil Deunyddiau Strwythurol (BOM) yn cynnwys pum haen swyddogaethol:
- Cefnogaeth rhwystr:Ewyn polyethylen cell caeedig (PE) 1.0 mm o drwch (dwysedd 65 kg/m3). Mae'r adeiledd celloedd caeedig yn rhwystr corfforol anhydraidd yn erbyn ymdreiddiad hylif, gan atal paratoadau llawfeddygol cyfun neu halwynog rhag cysylltu â'r dargludydd.
- Matrics Gludydd Perimedr:Gludydd sy'n sensitif i bwysedd acrylig pur (PSA) wedi'i groesgysylltu â phwysau meddygol wedi'i osod ar bwysau cot sych o 40 i 50 g/m2. Mae'r ffin gludiog yn ymestyn o leiaf 10 mm y tu hwnt i'r perimedr dargludol, gan angori'r plât i epidermis dynol gyda grym peel deinamig sy'n fwy na 5.5N / 25mm.
- Arweinydd Alwminiwm wedi'i Rolio: A 38 um thick, high-purity (>= 99.5%) gwe ffoil alwminiwm rholio. Caiff y ffoil ei stampio'n ddau hanner hollt cymesur wedi'u gwahanu gan fwlch deuelectrig an-ddargludol 5.0mm. Mae'r strwythur ffoil rholio yn darparu dargludedd trydanol isotropig a dargludiad thermol ochrol uchel, gan wasgaru crynodiad cerrynt lleol ar draws yr ôl troed dargludol llawn.
- Slab Hydrogel dargludol:Hydrogel polyacrylate dyfrllyd sy'n cael ei allwthio trwy orchudd marw slot ar drwch o 0.85 mm i 1.00 mm. Mae'r gel wedi'i gymhlethu â 2.5% i 3.5% o electrolytau clorid ffisiolegol a -polyolau gradd fferyllol, gan roi gwrthedd cyfaint isotropig o dan 15 Ohm-cm. Mae'r hydrogel yn ymestyn 3.0 mm heibio'r ffin ffoil alwminiwm, gan greu parth rhwystriant cynyddol i lawr sy'n atal yr effaith ymyl blaen.
- Leinin rhyddhau siliconedig:Ffilm cludwr PET optegol gradd 75 um wedi'i gorchuddio â silicon ychwanegol wedi'i halltu, yn cynnwys tab ymyl codi bys integredig ar gyfer plicio cyflym yn ystod cyfnodau llawfeddygol.
- Ar gyfer amrywiadau platiau cordiog, mae harnais gwifren hyblyg plwm 3.0 medr 3.0 (copr aml-linyn 20 AWG) yn cael ei gysylltu â'r tabiau ffoil alwminiwm trwy stancio mecanyddol aml-bwynt niwmatig. Mae'r gyffordd wedi'i photio o dan -chwistrelliad gwasgedd isel-gist lliniaru PVC wedi'i fowldio-sy'n gwrthsefyll grymoedd tynnu echelinol dros 40N. Mae'r cebl yn dod i ben mewn plwg benywaidd 2-pin wedi'i fowldio, o safon diwydiant, sy'n gydnaws â generaduron Medtronic Valleylab, ConMed, a Bovie.
Ar gyfer amrywiadau heb gordyn, mae'r ffoil alwminiwm yn ymestyn i mewn i dab cyswllt 25 mm wedi'i atgyfnerthu wedi'i orchuddio ag inc carbon dargludol, wedi'i gynllunio ar gyfer clampio i geblau dychwelyd y gellir eu hailddefnyddio. Mae platiau gorffenedig yn cael eu selio y tu mewn i godenni rhwystr PET/AL/PE amlhaenog o dan lanhau nitrogen i gadw lefelau lleithder hydrogel dros oes silff o 36 mis. Isafswm rhediad cynhyrchu contract OEM yw 5,000 o ddarnau ar gyfer unedau â llinyn a 10,000 o ddarnau ar gyfer cyfluniadau heb gordyn.
Nodweddion Allweddol
-
Ailddosbarthu Cyfredol Planr Cymesurol (3.5 × 10^7S/m Ffoil wedi'i Rolio Gwe Atal Gorlenwi Ffocal Cerrynt)
Pan fydd cerrynt radio-amledd monopolar yn dychwelyd o awyrennau llawfeddygol dwfn, mae'n mynd i mewn i'r hydrogel dargludol ar wahanol onglau digwyddiad. Mewn anwedd tenau-ffilmiau metelaidd wedi'u hadneuo (<10 um), the electrical sheet resistance of the thin conductor is high, creating a localized potential barrier that forces incoming current to discharge through the narrow perimeter edge nearest the surgical site. This boundary bottleneck produces thermal hotspots exceeding the 6.0C safety threshold. We eliminate this failure mode by utilizing a 38 um thick, high-purity (99.5% Al) rolled aluminum foil web exhibiting a bulk electrical conductivity exceeding 3.5 × 10^7 S/m. The high lateral electrical and thermal conductivity of the heavy-gauge rolled metal structure forms an equipotential plane: incoming RF current spreads instantly outward across the full X-Y footprint of the foil. Average current density across the 132 cm2 hydrogel contact area remains below 60 mA/cm2 under full-power cutting modes, distributing ther
-
Ymyl Hydrogel 3.0 mm-Graddiant Gorhang (Lliniaru'r Effaith Arwain-Effaith Ymyl a Dal Delta T Islaw 4.0C O dan Llwythi RF 700 mA)
Yn ystod llawdriniaeth electro monopolar, nid yw'r maes trydan yn unffurf: pigau dwysedd cerrynt ar berimedr y dargludydd sy'n wynebu'r fector electrod gweithredol oherwydd cynhwysedd effaith ymyl. Mewn platiau lle mae'r ffoil alwminiwm a'r hydrogel dargludol yn cael eu torri, mae'r graddiant maes trydan hwn yn gollwng egni thermol crynodedig (Q=I² R t) yn uniongyrchol i'r ymyl epidermaidd, gan achosi llosgiadau ymyl. Rydym yn dileu'r modd methiant hwn trwy ymestyn yr haen hydrogel dargludol 3.0 mm heibio perimedr y dargludydd ffoil alwminiwm ar bob ochr. Mae'r ymyl hydrogel heb ei gefn yn gweithredu fel gwrthydd cyfres ddosbarthedig, gan gamu i lawr yn raddol y potensial maes trydan cyn iddo ddod i ben ar y ffin ewyn inswleiddio. Mae delweddu thermol o dan brofion cymhwyster ANSI/AAMI HF18 (cyflwyno cerrynt RF 700 mA am 60 eiliad i mewn i ffantasi cyhyr halwynog gelatin) yn cadarnhau bod y cerrynt wedi'i ddosbarthu'n gyfartal ar draws yr ardal actif 132 cm2 gyfan, gan gyfyngu ar y codiad tymheredd dermal uchaf o dan 4.0C (ymhell islaw'r nenfwd rheoleiddiol 6.0C).
-
Sêl Acrylig Fflworinedig Hydroffobig Di-Polar (Ongl Gyswllt θ > Ffurfiant Trac Electrolyt Ataliedig 105 gradd o dan Dyfrhau Hylif)
Continuous fluid irrigation during surgical resection procedures presents a severe failure risk: saline and blood wicking under the return plate create conductive bypass routes, causing current to divert toward grounded metal fixtures on the operating table. Standard medical adhesives formulated with hydrophilic tackifiers swell and lose cohesive strength upon water contact, accelerating this fluid path formation. We construct our perimeter seal from a crosslinked, non-polar fluorinated pure acrylic adhesive applied onto a 1.0 mm closed-cell polyethylene foam carrier. The cured adhesive surface delivers a deionized water contact angle exceeding 105 degrees, actively repelling aqueous solutions through interfacial surface energy mismatches. The closed-cell PE foam backing provides an impermeable elastic seal, resisting fluid penetration under hydraulic pressures up to 15 kPa. The adhesive perimeter retains a continuous peel bond (>5.5N / 25mm) trwy 8 awr o amlygiad halwynog parhaus, atal hylif rhag mynd i mewn, codi ymyl, a llwybro cerrynt crwydr heb ei fonitro.
Ceisiadau
Uchel-Pŵer Agor Llawfeddygaeth Abdomenol a Pelfis
Plât gwasgarol safonol ar gyfer laparotomi archwiliadol, echdoriad yr afu, colectomi, a hysterectomi radical sy'n gofyn am dorri monopolar parhaus (hyd at 300W) a cheulo chwistrellu trwm (120W), gan ddarparu gwasgariad thermol cynhwysedd uchel heb losgiadau dermol.
Halwyn-Arthrosgopi ac Endwroleg Dyfrhau
Fe'i defnyddir yn ystod dadbridiad arthrosgopig ysgwydd/pen-glin ac echdoriad trawswrethrol o'r brostad (TURP), lle mae litrau o ddyfrhau hylif parhaus yn herio cyfanrwydd ymyl pad; mae'r{0}}ewyn cell caeedig yn atal hylif rhag mynd i mewn a-cylchu byr ymylol.
Arthroplasti Orthopedig Hir ac Offeryniaeth Asgwrn y Cefn
Cyfanswm arthroplasti clun (THA), cyfanswm arthroplasti pen-glin (TKA), a gweithdrefnau ymasiad asgwrn cefn aml-lefel yn ymestyn 4 i 8 awr; mae'r matrics hydrogel dŵr wedi'i rwymo'n uchel yn gwrthsefyll disychiad gweithredol tra'n glynu'n ddibynadwy o dan drin coes deinamig.
OEM a Label Preifat
-
Opsiynau Cordiedig yn erbyn Di-, Fformatau Pecynnu ac Offer Cysylltwyr : Return plates are manufactured in universal adult sizes (footprint >= 132 ardal weithredol cm2) wedi'i fformatio ar gyfer lleoliad llorweddol neu fertigol mewn perthynas â'r safle llawfeddygol. Rydym yn darparu dau blatfform cysylltiad trydanol:
·Fersiwn Cordiog:Cebl siaced PVC integredig 3.0m hyblyg gyda chwistrelliad-wedi'i fowldio â phlygiau ESU cyffredinol 2-pin, yn gwbl groes-gydnaws â generaduron Medtronic Valleylab, ConMed, Bovie ac Olympus.
·Fersiwn Heb-Cod(Tab-Arddull):Tab cyswllt 25 mm wedi'i atgyfnerthu yn cynnwys-traciau dargludol carbon arian wedi'i argraffu â sgrin, wedi'i beiriannu i gloi i mewn i geblau clamp plât dychwelyd rhyngwladol y gellir eu hailddefnyddio (fel cysylltwyr clamp ceg pysgod 11 mm safonol).
· Cyfluniadau Pecynnu:Wedi'i bacio 1 darn fesul cwdyn ar gyfer citiau theatr trawma acíwt, neu 5 darn fesul cwdyn ar gyfer llwyfannu cyfaint cyffredinol uchel NEU, wedi'i selio mewn twll-codenni rhwystr PET/AL/PE sy'n gwrthsefyll gydag argraffu cod bar UDI wedi'i deilwra.
-
Dau-Mecaneg Cadwyn Gyflenwi'r Ganolfan :Hollti gwe alwminiwm purdeb uchel, cotio hydrogel UV wedi'i fewnosod yn barhaus â nitrogen, torri marw cylchdro cyflymder uchel, ac argraffu tab carbon yn cael ei wneud yn frodorol y tu mewn i'n prif gyfleuster yn Tsieina. Stripio awtomataidd harnais gwifrau, gor-fowldio plwg, polion mecanyddol cebl, selio gwres hermetig cwdyn terfynol, profion rhwystriant trydanol 100%, a llwybr allforio cynhwysydd cefnfor wedi'i baleteiddio trwy ein canolfan yn Fietnam, gan warchod prynwyr B2B rhyngwladol rhag tariffau traul meddygol rhanbarthol a dyletswyddau Adran 301.
Ardystiadau
-
ANSI/AAMI HF18 & IEC 60601-2-2 Profi Math Llym :Mae lotiau cynhyrchu meistr yn cael eu dilysu'n gynhwysfawr mewn labordai annibynnol achrededig sy'n cadarnhau cydymffurfiad llym ag ANSI/AAMI HF18:2001/(R)2008 (Dyfeisiau Electro-lawfeddygol) ac IEC 60601-2-2 (Gofynion penodol ar gyfer diogelwch sylfaenol a pherfformiad hanfodol offer llawfeddygol amledd uchel). Mae'r cymhwyster yn cynnwys cyflwyno cerrynt RF 700 mA am 60 eiliad i mewn i ffantasiau cyhyr gelatin an-anwythol, gan gadarnhau bod y codiad tymheredd uchaf yn parhau i fod yn is na 4.0C (terfyn rheoliadol <6.0C), a phrofi dadelfennu dielectrig ar draws y sianel ryng-ffoil hyd at 3,000V DC.
-
Profi Biogydnawsedd Dermol ISO 10993:Mae croen{0}}cysylltu â hydrogeliau a gludyddion perimedr yn cael dilysiad swp mewn labordai achrededig sy'n cadarnhau cydymffurfiaeth ag ISO 10993-5 (In Vitro Cytotoxicity Grade 0), ISO 10993-10 (Sensiteiddio Croen: 0% ymateb alergaidd), ac ISO 10993-10% Indidiad Alergaidd=0.0). Mae'r cynulliad cyflawn yn 100% rwber naturiol heb latecs, heb ffthalad, ac mae'n cynnwys plastigyddion sero gwenwynig.
-
Rheolaethau System Gweithgynhyrchu MDSAP ac ISO 13485 :Mae llinellau trosi cyflymder uchel, gorsafoedd crimpio ceblau awtomataidd, a deciau rhwystr pecynnu yn gweithredu'n llym o fewn cyfleusterau sydd wedi'u hardystio i fframweithiau rheoleiddio ISO 13485:2016 a MDSAP (sy'n cwmpasu FDA UD 21 CFR 820, Health Canada, TGA Awstralia). Mae Cofnodion Hanes Dyfeisiau Electronig (DHR) heb eu torri yn dal dargludedd ffoil alwminiwm amrwd, cysondeb caliper hydrogel, boncyffion grym tynnu terfynell cebl, a chadw gwactod sêl cwdyn hermetig. /
Cwestiynau Cyffredin Technegol
C: Pam mae gosod plât dychwelyd oedolyn dros amlygrwydd esgyrnog neu feinwe craith yn achosi llosgiadau llawfeddygol, a sut mae cyfeiriadedd y cymhwysiad o'i gymharu â'r safle llawfeddygol yn effeithio ar ddwysedd cerrynt ymylol?
A: Nid yw dargludedd trydanol mewn meinwe dynol yn-homogenaidd: mae gan gyhyr ysgerbydol fasgwlaidd wrthedd trydanol isel (tua 150 Ohm-cm), tra bod meinwe adipose a meinwe craith ffibrog trwchus yn cyflwyno gwrthedd sylweddol uwch (yn amrywio o 1,500 i 2,500 Ohm{{7}Ohm). Mae asgwrn cortigol yn gweithredu fel ynysydd agos. Pan fydd plât dychwelyd yn cael ei gymhwyso dros amlygrwydd esgyrnog (ee, y crib iliac neu'r trochanter mwy), mae'r tafluniad mecanyddol yn cywasgu'r hydrogel, gan deneuo'r haen dielectrig a chanolbwyntio pwysau mecanyddol dros ardal ffocal fach. Ni all cerrynt dreiddio i'r asgwrn gwaelodol ac fe'i gorfodir yn ochrol i'r haenau bas, gwrthiannol iawn, y croen a'r adipose yn union uwchben yr asgwrn. Mae'r crynodiad hwn yn cynhyrchu pigau dwysedd cerrynt lleoledig (J=I / A) sy'n cynhyrchu gwres ohmig cyflym: P=J²·ρ
C: Sut mae cylched Monitro Ansawdd Cyswllt (REM/CQM) y generadur yn gwahaniaethu rhwng gwir ddatodiad pad a disicciad hydrogel, a beth sy'n sbarduno'r trothwy diffyg rhwystriant?
A: Mae unedau electrolawfeddygol modern yn defnyddio cylched pont AC ynysig sy'n chwistrellu signal holi foltedd isel parhaus (fel arfer 100 kHz i 140 kHz ar < 2.0 mA) ar draws haneri hollt y plât dychwelyd. Mae cyfanswm rhwystriant cylched (Zloop}) a fesurir gan y generadur yn cynnwys tair cydran mewn cyfres: Zloop=Z{gel1 + Ztissue + Zgel2.O dan amodau clinigol arferol ar glaf sy'n oedolyn, mae Zloop yn setlo rhwng 15 Ohm a 45 Ohm. Mae rhesymeg fewnol y generadur yn olrhain y llinell sylfaen hon: os yw'r rhwystriant yn dringo uwchlaw nenfwd absoliwt (135 Ohm ar systemau Valleylab) neu'n dangos cynnydd cam deinamig o fwy na 40% dros y llinell sylfaen a ddilyswyd, mae'r generadur yn atal cyflenwad ynni RF ac yn sbarduno larwm nam REM clywadwy a gweledol.
Gall OEMs generaduron electrolawfeddygol, arweinwyr caffael theatr llawdriniaethau ysbyty, a dosbarthwyr traul llawfeddygol ofyn am goflenni afradu thermol ANSI/AAMI HF18 achrededig, cromliniau rhwystriant holi REM ar draws llwyfannau generaduron lluosog, a phecynnau sampl gwerthuso 5-darn heb eu brandio mewn ffurfweddiadau llinynnol neu heb gordyn.
👉 [Gofyn am Becynnau Gwerthuso Plât Dychwelyd Electrolawfeddygol Oedolion]
Tagiau poblogaidd: platiau dychwelyd cleifion electrolawfeddygol tafladwy i oedolion, gweithgynhyrchwyr platiau dychwelyd cleifion electrolawfeddygol tafladwy Tsieina, cyflenwyr, ffatri
Manylebau
| Paramedr Dadansoddol | Llinell Sylfaen Peirianneg | Safon Profi |
| Mandad Rheoleiddio | ANSI/AAMI HF18:2001/(R)2008, IEC 60601-2-2 | Electrodau niwtral tafladwy |
| Topoleg Cylchdaith | Pensaernïaeth Hollti (Deuol-Foil) REM / CQM | Mesur gwahaniaethol |
| Maes Dargludol Gweithredol | >= 132 cm2 (Cyfanswm parth hydrogel dargludol) | Cydymffurfio â HF18 |
| Cyfanswm Ôl Troed | 210 mm x 125 mm (+/- 2.0 mm) | Hirgrwn / hirsgwar |
| Terfyn Cynnydd Thermol | Uchafswm Delta T <4.0C ar 700 mA RF am 60au | ANSI/AAMI HF18 (terfyn < 6.0C) |
| Haen Arweinydd | 38 um Wedi'i Rolio Uchel-Ffoil Alwminiwm Purdeb (99.5% Al) | Màs thermol uchel |
| Rhyng-Bwlch Hollti Ffoil | 4.0 mm i 6.0 mm Sianel Dielectric | Rhwystr dielectrig uchel |
| Rhwystr Ffoil Rhyng{0} | 15 Ohm i 45 Ohm ar 100 kHz (Llwyth meinwe oedolion) | Ffenestr REM Valleylab (5-135 Ohm) |
| Hydrogel dargludol | Gel Acrylig Croesgysylltiedig Isotonig (0.85 i 1.00 mm) | Gwrthedd cyfaint < 15 Ohm-cm |
| Perimedr Gludiog | >5.5N / 25 mm ar Cwpon Dur Di-staen | ASTM D3330 |
| Swbstrad Cludydd | 1.0 mm Ar Gau-Ewyn PE Crosslinked Cell (65 kg/m3) | Rhwystr hydroffobig |
| Leadwire & Plug | Cebl 3.0 m PVC wedi'i orchuddio â phlwg 2-pin wedi'i fowldio | Fersiwn cordio |
| Pecynnu a Pouchio | Bag Rhwystr Aml-Haenog PET/AL/PE wedi'i selio (1 neu 5 pcs) | Oes silff 36 mis |